ERO 2000

    Specifications

    Scanning head

    AK ERO 2080

    Interface

      1 VPP

    Cutoff frequency –3 dB

    600 kHz

    Electrical connection*

    Cable, 0.3 m or 1 m with D-sub connector (male), 15-pin

    Cable length

    30 m (with HEIDENHAIN cable)

    Voltage supply

    DC 5 V ± 0.25 V

    Current requirement

    < 85 mA (without load)

    Vibration 55 to 2 000 Hz

    Shock 6 ms

    500 m/s2 (EN 60 068-2-6)

    1000 m/s2 (EN 60 068-2-27)

    Operating temperature

    Storage temperature

    –10 °C to 70 °C

    –20 °C to 80 °C (in the packaging)

    Mass Scanning head

    5.5 g (without cable)

    Circular scale

    TKN ERO 2000

    TKN ERO 2001

    Measuring standard

    SUPRADUR phase grating on glass

    Measuring range

    360°

    45°

    Signal periods

    2500 over 360°

    Position error
    per signal period

    Typically ± 1.0''

    With compensation (e.g. in EIB 392): typically ± 0.2’’

    Position noise RMS

    Typically ± 0.04''

    Reference marks

    One

    Dimensions

    ¬ 18.6 mm x 0.75 mm

    9 mm x 18.6 mm x 0.75 mm

    Mech. permissible speed

    14 000 rpm

    Moment of inertia

    22 gmm2

    11 gmm2

    Protection EN 60 529

    IP 00

    Mass

    0.56 g

    0.36 g

    * Please select when ordering