LC 195

    Specifications

    Specifications

    LC 195 F

    LC 195 M

    LC 195 S

    Measuring standard

    Coefficient of linear expansion

    DIADUR glass scale with absolute track and incremental track, grating period 20 µm

    αtherm  8 x 10-6 K-1

    Accuracy grade*

    ± 3 µm up to measuring length 3 040 mm; ± 5 µm

    Measuring length ML*
    in mm

    140, 240, 340, 440, 540, 640, 740, 840, 940, 1040, 1140, 1240, 1340, 1440,

    1540, 1640, 1740, 1840, 2040, 2240, 2440, 2640, 2840, 3040, 3240, 3440, 3640, 3840,

    4040, 4240

    Functional safety*

    Option1)

    Interface

    Fanuc Serial Interface αi interface

    Mitsubishi high speed interface

    DRIVE-CLiQ

    Ordering designation

    Fanuc05

    Mit03-04

    DQ01

    Resolution

    At ± 3 µm

    At ± 5 µm

    αi interface/α interface

    0.00125 µm/0.010 µm

    0.0125 µm/0.050 µm

    0.001 µm

    0.010 µm

    Diagnostics interface

    Digital

    Electrical connection

    Separate adapter cable (1 m/3 m/6 m/9 m) connectable on both sides to mounting block

    Cable length

    ≤ 50 m

    ≤ 30 m

    ≤ 30 m2)

    Voltage supply

    3.6 V to 14 V DC

    10 V to 28.8 V DC

    Power consumption (max.)

    3.6 V: ≤ 1.1 W; 14 V: ≤ 1.3 W

    10 V: ≤ 1.5 W; 28.8 V: ≤ 1.7 W

    Current consumption (typical)

    5 V: 140 mA (without load)

    24 V: 46 mA (without load)

    Traversing speed

    ≤ 180 m/min

    Required moving force

    ≤ 4 N

    Vibration 55 to 2 000 Hz
    affecting the

    Shock 11 ms

    Acceleration

    Housing: ≤ 200 m/s2 (EN 60 068-2-6)

    Scanning unit: ≤ 200 m/s2 (EN 60 068-2-6)

    ≤ 300 m/s2 (EN 60 068-2-27)

    ≤ 100 m/s2 in measuring direction

    Operating temperature

    0 °C to +50 °C

    Protection EN 60 529

    IP 53 when installed according to instructions in the brochure, IP 64 with sealing air from DA 400

    Weight

    0.55 kg + 2.9 kg/m measuring length

    * Please select when ordering

    1) For dimensions and specifications, see separate Product Information document

    2) Greater cable lengths in preparation