LC 1x5

    Specifications

    Specifications

    LC 115

    LC 185

    Measuring standard

    Coefficient of linear expansion

    DIADUR glass scale with absolute track and incremental track, grating period 20 µm

    αtherm  8 x 10-6 K-1

    Accuracy grade*

    ± 3 µm up to measuring length 3 040 mm; ± 5 µm

    Measuring length ML*
    in mm

    140, 240, 340, 440, 540, 640, 740, 840, 940, 1040, 1140, 1240, 1340, 1440

    1540, 1640, 1740, 1840, 2040, 2240, 2440 2640, 2840, 3040, 3240, 3440, 3640,3840

    4040, 4240

    Functional safety*

    Option1)

    Interface

    EnDat 2.2

    Ordering designation

    EnDat22

    EnDat02

    Resolution At ± 3 µm

    At ± 5 µm

    0.001 µm

    0.010 µm

    0.005 µm

    0.010 µm

    Diagnostics interface

    Digital

    Clock frequency

    Calculation time tcal

    ≤ 16 MHz

    ≤ 5 µs

    ≤ 2 MHz

    ≤ 5 µs

    Incremental signals

      1 VPP

    Signal period

    Cutoff frequency –3 dB

    20 µm

    150 kHz

    Electrical connection

    Separate adapter cable (1 m/3 m/6 m/9 m) connectable on both sides to mounting block

    Cable length

    ≤ 100 m2)

    ≤ 150 m2)

    Voltage supply

    3.6 V to 14 V DC

    Power consumption (max.)

    3.6 V: ≤ 1.1 W; 14 V: ≤ 1.3 W

    Current consumption (typical)

    5 V: 140 mA (without load)

    Traversing speed

    ≤ 180 m/min

    Required moving force

    ≤ 4 N

    Vibration 55 to 2 000 Hz
    affecting the

    Shock 11 ms

    Acceleration

    Housing: ≤ 200 m/s2 (EN 60 068-2-6)

    Scanning unit: ≤ 200 m/s2 (EN 60 068-2-6)

    ≤ 300 m/s2 (EN 60 068-2-27)

    ≤ 100 m/s2 in measuring direction

    Operating temperature

    0 °C to +50 °C

    Protection EN 60 529

    IP 53 when installed according to instructions in the brochure, IP 64 with sealing air from DA 400

    Weight

    0.55 kg + 2.9 kg/m measuring length

    * Please indicate when ordering 1) For dimensions and specifications, see separate Product Information document

    2) With HEIDENHAIN cable, clock frequency ≤ 8 MHz