Cable |
Radio and infrared |
|
Tool touch probe |
TT 160 |
TT 460 |
Probe accuracy |
≤ ±15 µm |
|
Probe repeatability Repeated probing from one direction |
2 s ≤ 1 µm at a probing velocity of 1 m/min Typical values: 2 s ≤ 1 µm at a probing velocity of 3 m/min 2 s ≤ 4 µm at a probing velocity of 5 m/min |
|
Deflection of probe contact |
≤ 5 mm in all directions |
|
Deflection force |
Axial: approx. 8 N Radial: approx. 1 N |
|
Probing velocity |
≤ 5 m/min |
|
Protection EN 60 529 |
IP68 |
|
Operating temperature |
10 °C to 40 °C |
|
Storage temperature |
–20 °C to 70 °C |
|
Mass |
≈ 0.3 kg |
≈ 0.4 kg |
Mounting on the |
|
|
Electrical connection |
M12 flange socket, 8-pin |
– |
Cable length |
≤ 25 m |
– |
Voltage supply |
DC 10 V to 30 V/≤ 100 mA (without load) |
2 batteries (rechargeable or non-rechargeable) |
Operating time |
– |
Typically 90 h3) with alkaline batteries (included in delivery); Typically 400 h3) possible with lithium batteries |
Interface* |
HTL |
HTL, EnDat 2.2 |
Output signals |
|
– |
HTL signal levels |
UH ≥ 20 V at –IH ≤ 20 mA UL ≤ 2.8 V at IL ≤ 20 mA at DC 24 V rated voltage |
– |
Signal transmission |
Cable |
Radio or infrared transmission (selectable) |
Transceiver unit |
– |
|
TT switch-on/off |
– |
Radio or infrared signal (selectable) from SE |
* Please select when ordering 1) Reduced operating time if there is much surrounding radio traffic, or short but frequent probing intervals 2) SE shared by TS 460 and TT 460, see page 28 3) With EnDat interface 4) Reduced operating time if there is high surrounding radio traffic or if probing intervals are short and frequent |