Specifications

    Specifications

    Specifications

    Standard

    Option

    Components

    MC main computer

    CC or UEC controller units

    BF TFT flat-panel display with soft keys (15-inch or 19-inch)

    TE control panel (suitable for 15-inch or 19-inch screens)

    Operating system

    HEROS 5 real-time operating system for machine control

    Memory

    RAM memory: 4 GB

    Program memory: SSDR approx. 32 GB

    HDR approx. 160 GB

    Input resolution and display step



    23

    23

    Linear axes: to 0.1 µm

    Angular axes: to 0.000 1°

    Linear axes: to 0.01 µm

    Rotary axes: to 0.000 01°

    Input range

    Maximum 999 999 999 mm or 999 999 999°

    Interpolation




    9


    8

    Linear in 4 axes

    Linear in 5 axes (requires an export permit)

    Circular in 2 axes

    Circular in 3 axes with tilted working plane

    Helical: superimposition of circular and straight paths

    Block processing time

    0.5 ms (3-D straight line without radius compensation)

    Axis feedback control


    Position loop resolution: Signal period of the position encoder/1024

    Position controller cycle time: 200 µs (100 µs with option 49)

    Speed controller cycle time: 200 µs (100 µs with option 49)

    Current controller cycle time: minimum 100 µs (minimum 50 µs with option 49)

    Range of traverse

    Maximum 100 m (3937 inches)

    Spindle speed

    Maximum 100 000 rpm (with 2 pole pairs)

    Error compensation



    Linear and nonlinear axis error, backlash, reversal peaks during circular movements,
    reversal error, thermal expansion

    Static friction, sliding friction

    Data interfaces











    18

    One each RS-232-C/V.24 max. 115 kbps

    Extended data interface with LSV2 protocol for remote operation of the TNC over the
    data interface with the HEIDENHAIN software TNCremo or TNCremoPlus

    2 x Gigabit Ethernet interface 1000BASE-T

    5 x USB (1 x front USB 2.0, 4 x USB 3.0)

    HEIDENHAIN-DNC for communication between a Windows application and TNC (DCOM interface)

    Diagnostics

    Fast and simple troubleshooting through integrated diagnostic aids

    Ambient temperature

    Operation: +5 °C to +40 °C

    Storage: –20 °C to +60 °C